    In HVT (Hollywood Technology), any voltage above 11 kilo-volts is considered to be from the high voltage range. It can either be alternating or dc. Tastes industries are supplied with this variety of voltages in the national grid while some generates their particular high voltage power using power generators. Higher than normal voltages are often stepped down to some specific lower voltages, to perform their electrical machinery for example motors, heaters, HVAC systems, and the like. Of those industries, regular checks should be conducted by authorized personnel to guage the health of their equipment. Equipment tests are very essential in determining the steadiness of the machine in order to avoid equipment breakdown and massive production losses. These tests also aid in determining in case a newly purchased tools are worth, before installing it. Most manufacturers use high voltage testing to try the insulation with their equipment before supplying them on their customers.

    Some great benefits of applying high voltage insulation testing are generally looked down upon by a lot of industries, being a technique of discovering the conditionality of these electrical equipment. This could be greatly attributed to the reality that much pressure and emphasis is usually wear production activities on the cost of proactive upkeep of the device. The best and effective insulation on an electrical machine is very important for its correct operation each and every time. Since insulation of it technology degrades as time passes, the respective electrical department for almost any industry should be regularly conducting regular check-ups for machines in their normal working schedule. This should be done to even low and medium voltage systems.

    Generally, a four stage process is followed. The stages are briefly described below:

    In-process testing

    This is the most elementary process which can be done even for the readily installed equipment, so long as it’s not at all running. This procedure demands the usage of a meggering instrument to check the insulation integrity with the coils prior to it being linked to phases, neutral, and earth. In some cases, a multimeter may also be used. Inter-winding and winding-to-body resistances are checked at this time. Therefore, the dielectric withstanding voltage and insulation resistance from the coil can be discovered.

    Ancillary Equipment Testing

    This implies testing for insulation resistance and dielectric withstanding voltage for interconnecting cables, high profile bushings, busbars, and terminations. This is often conducted once the components are interconnected or separated.

    Generator Assembly Test

    In such cases the generator is visually inspected. Cleaning is performed along with the machine’s stability is additionally assessed. The pulse in the machine is assessed using a special display instrument. The gear can also be meggered for insulation resistance and dielectric withstanding voltage test.

    One of many a few in testing equipment are; voltage and right testing equipment. For the most dependable results testing voltage should be adequate to effectively measure the insulating resistance. However, it shouldn’t be too much to overstress the gear insulation. The best testing equipment which could effectively store results lets them be kept in a computer for archiving and analysis. This action saves time and cuts down on the probability of error.