    In HVT (Hollywood Technology), any voltage above 11 kilo-volts is considered to be within the high voltage range. It could either be alternating or household power. Tastes industries are supplied using this range of voltages through the national grid while many generates their very own high profile power using power generators. Extremely high voltages are usually stepped as a result of some specific lower voltages, to own their electrical machinery like motors, heaters, HVAC systems, amongst others. Because of these industries, regular checks have to be conducted by authorized personnel to assess the fitness of their equipment. Equipment tests are very essential in determining the steadiness of the machine to be able to avoid equipment breakdown and big production losses. These tests also help out with determining in case a newly purchased tools are worth, before setting it up. Most manufacturers use high voltage testing to test the insulation of these equipment before supplying them with their customers.

    The advantages of applying high profile insulation testing are generally looked down upon by a lot of industries, as a technique of learning the conditionality with their electrical equipment. This is greatly caused by the truth that much pressure and emphasis is usually wear production activities with the expense of proactive repair of the apparatus. A dependable and effective insulation to have an electrical machine is most important for its correct operation each time. Since insulation of equipment degrades as time passes, the respective electrical department for just about any industry have to be regularly conducting regular check-ups for machines within their normal working schedule. This should be done to even low and medium voltage systems.

    In most cases, a four stage process is followed. The stages are briefly described below:

    In-process testing

    This is actually the simplest process that may be done even for the readily installed equipment, providing that it is not running. This process demands the usage of a meggering instrument to evaluate the insulation integrity of the coils prior to it being attached to phases, neutral, and earth. In some instances, a multimeter doubles. Inter-winding and winding-to-body resistances are checked at this point. Therefore, the dielectric withstanding voltage and insulation resistance from the coil can be established.

    Ancillary Equipment Testing

    This involves testing for insulation resistance and dielectric withstanding voltage for interconnecting cables, high voltage bushings, busbars, and terminations. This could be conducted in the event the components are interconnected or separated.

    Generator Assembly Test

    In cases like this the generator is visually inspected. Cleaning is performed and the machine’s stability can be assessed. The pulse from the machine is closely monitored employing a special display instrument. The apparatus can be meggered for insulation resistance and dielectric withstanding voltage test.

    Among the considerations in testing equipment are; voltage and right testing equipment. For dependable results testing voltage ought to be high enough to effectively study the insulating resistance. However, it should not be way too high to overstress the equipment insulation. The appropriate testing equipment which may effectively store results permits them to be held in some type of computer for archiving and analysis. This treatment saves some time and cuts down on the likelihood of error.